Customization: | Available |
---|---|
Application: | Insulators, Insulation, Electrical Base, Fccl, FPC |
Color: | Yellow |
Still deciding? Get samples of US$ 0/kg
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | Test requirement | unit | Requirement | ||
12.5μm | 25μm | 50μm | |||
width | Take the middle value of three tests | mm | 520±1.6 or 1028±1.6 | ||
thickness | Take the middle value of 27 points | µm | 10.2-15.2 | 23-27 | 48-52 |
Tensile strength | Sample size 15mm×250mm; separation velocity50mm/min | Mpa | ≥138 | ≥165 | ≥165 |
Elongation | % | ≥35 | ≥40 | ≥50 | |
Shrinkage rate | 200ºC 2h | ‰ | ≤1.0 | ≤1.2 | |
electric strength | Take the middle value of 21 testing points in air | MV/m | ≥120 | ≥235 | ≥195 |
Color difference | Compare sample | / | No obvious difference | ||
Surface tension | temperature23ºC±2ºC Relative humidity 50%±5% |
Dyne/cm | ≥58 |